Goodrive30 Series VFD Keypad operation procedure
-30-
the parameter is saved to the control board first, and then the level-2 menu is returned,
displaying the next function code. If you press the PRG/ESC key, the level-2 menu is returned
directly, without saving the set value of the parameter, and the current function code is
displayed.
If you enter the level-3 menu but the parameter does not have a digit blinking, the parameter
cannot be modified due to either of the following reasons:
1) It is read only. Read-only parameters include actual detection parameters and running
record parameters.
2) It cannot be modified in running state and can be modified only in stopped state.
Example: Change the value of P00.01 from 0 to 1.
The units place
is blinking
All digits are
blinking
Note: When setting the value, you can press and + modify the value.
SHIFT
PRG
ESC
PRG
ESC
PRG
ESC
PRG
ESC
DATA
ENT
DATA
ENT
DATA
ENT
The units place
is blinking
The units place is
blinking
The units place is blinking
Figure 4-4 Modifying a parameter
4.3.2 Setting a password for the VFD
Goodrive30 series VFDs provide password protection function to users. Set P07.00 to gain the
password and the password protection becomes effective 1 minute later after retreating from
the function code editing state. Press PRG/ESC again to the function code editing state,
"0.0.0.0.0" will be displayed. Unless using the correct password, you cannot enter it.
To disable the password protection function, you need only to set P07.00 to 0.
All digits are blinking
PRG
ESC
PRG
ESC
PRG
ESC
PRG
ESC
DATA
ENT
DATA
ENT
DATA
ENT
The units place is blinking
The units place is blinking
The units place is blinking The units place is blinkingThe units place is blinking
Note: When setting the value, you can press and + modify the value.
SHIFT
Figure 4-5 Setting a password