Goodrive30 Series VFD Function parameter list
-82-
Function
code
Name
Description
Default
Modify
P07.55
Input
terminal
status at
2nd-last
fault
0
P07.56
Output
terminal
status at
2nd-last
fault
0
P08 group Enhanced functions
Function
code
Name
Description
Default
Modify
P08.00
ACC time 2
Refer to P00.11 and P00.12 for detailed
definition.
The VFD has four groups of ACC/DEC time
which can be selected by P5 group. The first
group of ACC/DEC time is the factory default
one.
Setting range: 0.03600.0s
Model
depended
P08.01
DEC time 2
Model
depended
P08.02
ACC time 3
Model
depended
P08.03
DEC time 3
Model
depended
P08.04
ACC time 4
Model
depended
P08.05
DEC time 4
Model
depended
P08.06
Running
frequency
of jog
The function code is used to define the reference
frequency during jogging.
Setting range: 0.00HzP00.03 (max. output
frequency)
5.00Hz
P08.07
ACC time
for jog
ACC time for jogging means the time needed for
the VFD to accelerate from 0Hz to the max.
output frequency (P00.03).
DEC time for jogging means the time needed for
the VFD to decelerate from the max. output
frequency (P00.03) to 0Hz.
Setting range: 0.03600.0s
Model
depended
P08.08
DEC time
for jog
Model
depended

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the INVT Goodrive30 VFD Series and is the answer not in the manual?

INVT Goodrive30 VFD Series Specifications

General IconGeneral
BrandINVT
ModelGoodrive30 VFD Series
CategoryInverter
LanguageEnglish

Related product manuals