Goodrive30 Series VFD Function parameter list
-89-
DOWN
terminal
frequency
decrementa
l change
rate
Action
selection at
power-off
during
frequency
setting
0x000–0x111
Ones place: Action selection at power-off during
frequency adjusting through digitals.
0: Save the setting at power-off
1: Clear the setting at power-off
Tens place: Action selection at power-off during
frequency setting through Modbus
communication
0: Save the setting at power-off
1: Clear the setting at power-off
Hundreds place: Action selection at power-off
during frequency setting through other
communication methods
0: Save the setting at power-off
1: Clear the setting at power-off
MSB of
initial power
consumptio
n
This parameter is used to set the initial power
consumption.
Initial power consumption =P08.48*1000+
P08.49
Setting range of P08.48: 0–59999 kWh ( k)
Setting range of P08.49: 0.0–999.9 kWh
LSB of
initial power
consumptio
n
This function code is used to enable magnetic
flux braking.
0: Invalid.
100–150: A greater coefficient indicates greater
braking strength.
The VFD can quickly slow down the motor by
increasing the magnetic flux. The energy
generated by the motor during braking can be
transformed into heat energy by increasing the