Table 50: Error messages
Meaning of the error message
00 0 Invalid error Information: Only for connected service module. An invalid
(corrupted) entry in the error buffer has been marked by this
error number.
The system time entry is set to 0.
No measures required.
1 Invalid error detected and corrected Information: Only for connected service module. An invalid
(corrupted) error entry has been detected in the permanent
event memory and corrected.
2 Error cleared Information: The active errors have been acknowledged.
No measures required.
4 Serial number/device type changed
(module change)
Information: Only for connected service module. An
exchangeable error buffer has been plugged into another
device.
No measures required.
7 Log add-on: Permanent event memory
and FSM module
Information: Entry in permanent event memory. “An
additional record was found.”
No measures required.
8 Servo drive switched on Information: Entry in permanent event memory.
No measures required.
9 Servo drive safety parameters revised Information: Entry in permanent event memory.
No measures required.
11 FSM: Module change (previous type):
Permanent event memory and FSM
module
Information: Entry in permanent event memory.
No measures required.
12 FSM: Module change (current type):
Permanent event memory and FSM
module
Information: Entry in permanent event memory.
No measures required.
01 0 Stack overflow Incorrect firmware?
If necessary, reload the standard firmware.
Contact the Technical Support.