Test Report No.: 17702074 003
Part I of II
category in accordance with the requirements of EN
60825-1:2007.
The laser shall be fitted to the machine so that warnings
on the laser itself remain visible.
All provisions from the laser manufacturer associated to
the installation and the use of the laser shall be fulfilled.
The instruction for use of the laser shall be repeated in
the instruction manual. Warning label and advice on use
of eye protection if any shall be provided on the machine
near the operator's position.
Verification: By checking the relevant drawings and
inspection of the machine.
NOTE For the laser characteristics the information from the
manufacturer of the laser can be useful.
If the machine is fitted with flexible hoses for chip and
dust extraction, the hoses shall be able to lead charge to
earth potential.
Verification: By checking the relevant drawings and
inspection of the machine.
The machine shall be designed so that it is not possible to
mount saw blades or grooving tools with dimensions
larger than those for which it has been designed.
Also see 5.3.2.2, 6.2 and 6.3.
Verification: By checking the relevant drawings and
inspection of the machine.
Supply disconnection (Isolation)
The requirements of Clause 5 of EN 1037:1995+A1:2008
apply and in addition:
The electrical isolator shall be in accordance with the
requirements in EN 60204-1:2006, 5.3.
When fitted with a plug to connect the machine to a 3-
phase electrical supply, this plug may incorporate a phase
inverter.
If the machine is fitted with a DC injection braking system,
the electrical supply disconnecting device shall be:
Plug used and the pug is
under the operators’
supervision.