Test Report No.: 17702074 003
Part I of II
Page 11 of 72
EN 1870-19:2013
Clause
Requirement
Remarks - Results
Verdict
b) set for the maximum adjustment time.
The speed for the powered movement of the fence(s)
shall be ≤ 25 m min
-1
. See also 5.3.7.4
Verification: By checking the relevant drawings and/or
circuit diagrams, measurement, inspection of the machine
and relevant functional testing of the machine.
5.2.8
Interlocking of guards, movements and functions
N/A
If not otherwise specified in this document the safety
related part of the interlocking system of guards,
movements and functions shall be at least PL=c in
accordance with the requirements of EN ISO 13849-
1:2008.
Verification: By checking the relevant drawings and/or
circuit diagrams and inspection of the machine and
functional testing of the machine.
N/A
5.2.9
Failure of the power supply
P
On electrically driven machines in the case of supply
voltage interruption an automatic restart after the
restoration of the supply voltage shall be prevented in
accordance with the requirements of EN 60204-1:2006,
7.5 paragraphs 1 and 3.
The automatic restart of the machine dangerous
movements shall be prevented after restoration in the
case of supply interruption of the pneumatic or hydraulic
energy (where fitted).
Verification: By checking the relevant drawings and/or
circuit diagrams, inspection of the machine and relevant
functional testing of the machine.
Electromagnetic main
switch is used. Automatic
restart cannot occur.
P
5.2.10
Failure of the control circuits
P
The requirements of Clause 6 of EN 1037:1995+A1:2008
shall apply and in addition:
The control circuits shall be designed so that a break in
any circuit (e.g. broken wire, ruptured pipe or hose) will
not result in the loss of a safety function, e.g. involuntary
start of the machine, saw blade unclamping or loss of
workpiece clamping (if fitted) in accordance with EN
60204-1:2006 and EN ISO 4414:2010.
See also 5.2.1.
Verification: By checking the relevant drawings and/or
circuit diagrams, inspection of the machine and relevant
The start button can only
be operated by finger. All
conductive parts which
may contact with live
conductors are bonded and
connected to the earth.
P