Test Report No.: 17702074 003
Part I of II
for at least 15 min at idle speed;
d) verify that the actual spindle speed is within ± 10 % of
the intended speed.
The un-braked run-down time shall be measured as
follows:
a) start the saw spindle drive motor and run at the
intended speed (no load) for 1 min;
b) cut power to the saw spindle drive motor and measure
the un-braked run-down time;
c) repeat steps a) and b) twice more.
The un-braked run-down time is the average of the three
measurements taken.
The motor is equipped with
mechanical brake.
The braked run-down time shall be measured as follows:
a) start the saw spindle drive motor and run at the
intended speed (no load) for 1 min;
b) activate the saw spindle drive stop and measure the
braked run-down time;
c) allow the saw spindle to remain stationary for 1 min;
d) repeat steps a) to c) nine times.
The braked run-down time is the average of the ten
measurements taken. All measured values shall be less
than 10 s.
Average run-down time is:
TS250: 6.0s
TS250B: 5.3s
Maximum rundown time
measured is less than 10s.
Relationship between this European Standard and the
Essential Requirements of EU Directive 2006/42/EC
End of Test Report 17702074 003 part I of II.