The test loads shall be applied to the saw blade guard at
40 mm higher than the lowest point of the first in-feed
roller and directly above the furthermost point of the lower
edge (excluding the in-feed roller support) which is
parallel to the table (see Figure G.2).
The measuring point A shall be located at the same point
where the test load is applied (see Figure G.2).
The measuring point B shall be located at a point on the
top edge directly above the saw blade spindle axis (see
Figure G.2).
Under a test load F of 20 N the deflections D of the saw
blade guard shall be as follows:
a) ≤ 8 mm at measuring point A;