Test Report No.: 17702074 003
Part I of II
Page 2 of 72
EN 1870-19:2013
Clause
Requirement
Remarks - Results
Verdict
4
List of significant hazards
--
This clause contains all significant hazards, hazardous
situations and events (see EN ISO 12100:2010), identified
by risk assessment as significant for the machines as
defined in the scope and which require action to eliminate
or reduce the risk. This document deals with these
significant hazards by defining safety requirements and/or
measures or by reference to relevant standards.
These hazards are listed in Tables 1 and 2.
Informative clause.
--
5
Safety requirements and/or measures
P
5.1
General
P
The machine shall comply with the safety requirements
and/or protective measures of Clause 5.
In addition, the machine should be designed according to
the principles of EN ISO 12100:2010 for hazards relevant
but not significant, which are not dealt with by this
document (e.g. sharp edges of the machine frame).
For guidance in connection with risk reduction by design,
see EN ISO 12100:2010, 6.2, and for safeguarding
measures, see EN ISO 12100:2010, 6.3.
Considered.
P
5.2
Controls
P
5.2.1
Safety and reliability of control systems
P
5.1.1.1
General
P
For the purpose of this document, safety related part of a
control system means the system from the initial device,
e.g. actuator or position detector or sensor up to and
including the power control element of the final machine
actuator, e.g. motor or brake. Safety related parts of the
control system of this machine comprise parts concerning
the following functions and they shall fulfil at least the
requirements of the PL given below in accordance with
the requirements of EN ISO 13849-1:2008:
a) starting and restarting: PL=c (see 5.2.3);
b) prevention of unexpected start up: PL=c (see 5.2.3,
5.2.9);
c) normal stopping: PL=c (see 5.2.4);
Start/stop control is
hardwired. Category 1 and
PL=c achieved.
P