Section 9 Specification
SECTION 9
Specification
Type of emission PON
Display type Raster scan, PPI method, vertically long display
Display panel 6.5-inch high contrast color LCD
Range scale 0.125, 0.25, 0.5, 0.75, 1.5, 3, 6, 12, 24nm
Range resolution 25m max.
Minimum detective range 25m max.
Range scale accuracy 1.5% of the maximum operating range or 70m,
whichever larger.
Bearing accuracy ±1 degree max.
Bearing display mode Head-up, North-up, Course-up
Ambient conditions Temperature
Scanner -15°C + 55°C
Equipment other than scanner: -10°C +50°C
Relative humidity
All equipment: +35°C, 95% RH
Vibration
All equipment:
Amplitude 3 mm (0 to 500cpm)
Amplitude 0.75mm (500 to 1500cpm)
Amplitude 0.2 mm (1500 to 3000cpm)
Power consumption approx. 50W at DC12V
Power supply input fluctuation
DC10.2 16V
Pre-heating time approx. 90 sec
EMC FCC/IC/R&TTE
Illumination of LCD 330 cd/m
2
Control of brightness 10 step
Control of contrast 10 step