67
Section 3 Operation
ON
NAV ALARM >
RADAR ALARM>
TEMP. ALARM>
CLOCK ALARM>
BUZZER
ALARM SETTING
OFF
IN
4
CONTINUOUS
GUARD ZONE
ALARM MODE
ALARM LEVEL
ALARM SETTING
BZ ALARM
RADAR ALARM
GUARD ZONE
OFF ON
Setting GUARD ZONE
The Guard Zone may be a zone completely surrounding the vessel
or a partial trapezoidal zone to monitor targets entering or departing
the specified area.
Targets entering or leaving the guard zone will sound audible and
visible alerts to the operator. In the “IN” alarm mode, an alarm will
sound if a target enter the area. In the “OUT” alarm mode the alarm
will sound if a target leaves the prescribed area. This type of alarm is
useful for monitoring during an anchor watch, when cruising with
other vessels, pair trawling, or towing operation.
An alarm is sounded when any (apparent) target returning an echo
above the noise threshold is detected. If sea clutter, or other incidental
echoes trip the alarm, adjust the gain control and/or the sea clutter to
avoid this false alarming.
[To open the "RADAR ALARM" menu]
•Press
MENU
MENU
and select “ALARM SETTING>” and push the
Joystick
, the “ALARM SETTING” menu is displayed.
•Select the “RADAR ALARM>” and push the
Joystick
, the “RADAR
ALARM” menu is displayed.
[To turn on or to turn off GUARD ZONE]
•Select the “GUARD ZONE” in RADAR ALARM menu and push
the
Joystick
, the “GUARD ZONE” pull-down menu is displayed.
Change settings to ON/OFF by
Joystick
right or left and push
Joystick
.
The guard zone is appeared that you used.
[To select IN alarm or OUT alarm]
•Select the “ALARM MODE” in RADAR ALARM menu and push
the
Joystick
, the “ALARM MODE” pull-down menu is displayed.
Change settings to IN/OUT by
Joystick
right or left and push
Joystick
.
The “I” or “O” and ALARM LEVEL will be displayed in the upper
right corner of the screen.
ALARM MODE
IN OUT