Table 45: EX Series Switch Environmental Tolerances
Switch or
device
Environment Tolerance
Altude Relave Humidity Temperature Seismic
EX2200-C
No performance
degradaon up to
5,000 feet (1524
meters)
Normal operaon
ensured in the relave
humidity range 10%
through 85%
(noncondensing)
Normal operaon ensured
in the temperature range
32° F (0° C) through
104° F (40° C) at
altudes up to 5,000 
(1,524 m).
For informaon about
extended temperature
SFP transceivers
supported on EX2200
switches, see Pluggable
Transceivers Supported
on EX2200 Switches.
Complies with
Zone 4
earthquake
requirements as
per GR-63, Issue
4.
EX2200
(except
EX2200-C
switches)
No performance
degradaon up to
10,000 feet
(3048 meters)
Normal operaon
ensured in the relave
humidity range 10%
through 85%
(noncondensing)
Normal operaon ensured
in the temperature range
32° F (0° C) through
113° F (45° C)
Complies with
Zone 4
earthquake
requirements as
per GR-63, Issue
4.
EX2300-C No performance
degradaon up to
5,000 feet
(1524 meters)
Normal operaon
ensured in the relave
humidity range 10%
through 85%
(noncondensing)
Normal operaon ensured
in the temperature range
32° F (0° C) through
104° F (40° C)
Complies with
Zone 4
earthquake
requirements as
per GR-63, Issue
4.
EX2300
(except
EX2300-C
switches)
No performance
degradaon up to
13,000 feet
(3962 meters) at
104° F (40° C) as
per GR-63
Normal operaon
ensured in the relave
humidity range 10%
through 85%
(noncondensing)
Normal operaon ensured
in the temperature range
32° F (0° C) through
113° F (45° C)
Complies with
Zone 4
earthquake
requirements as
per GR-63, Issue
4.
121