Switch Fabric Module in an EX9200 Switch
The Switch Fabric serves as the central nonblocking matrix through which all network data passes.
Switch Fabric modules (SF modules) are installed horizontally on the front panel of the switch chassis.
You can install either one or two SF modules in an EX9204 or EX9208 switch and two or three SF
modules in an EX9214 switch. A base-conguraon EX9204 or EX9208 switch has only one SF module,
and a base-conguraon EX9214 switch has two SF modules. See
EX9204 Switch Conguraons
,
EX9208 Switch Conguraons
, or "EX9214 Switch Conguraons" on page 9.
In EX9204 and EX9208 switches, you can add a second SF module to the conguraon for host
subsystem redundancy. In EX9214 switches, you can add a third SF module to the conguraon for host
subsystem redundancy. If two SF modules are installed, one SF module funcons as the primary and the
other funcons as the backup. If the primary SF module or its components fails or is removed, the
backup module takes the role of primary.
The Roung Engine module (RE module) installs directly into a slot on the SF module. The Switch Fabric
contains logic that determines which Roung Engine is the primary. The primary Roung Engine controls
many internal funcons of the SF module.
The backup SF module is hot-insertable and hot-removable, but the primary SF module is only hot-
insertable.
The key funcons of the Switch Fabric are:
• Monitor and control system funcons
• Interconnecon of all line cards
• Clocking, system resets, and boong control
• Roung Engine carrier
67