NOTE: Aer you power on a power supply, wait for at least 60 seconds before you turn it o.
Aer you power o a power supply, wait for at least 60 seconds before you turn it back on.
If the system is completely powered o when you switch on a power supply, the RE module
boots as the power supply completes its startup sequence. If the Roung Engine nishes boong
and you need to power o the system again, rst issue the CLI request system halt command.
Aer you power on a power supply, it can take up to 60 seconds for status indicators such as
power supply LEDs and the show chassis operaonal mode CLI command display to indicate that
the power supply is funconing normally. Ignore any error indicators that might appear during
the rst 60 seconds.
Connecng DC Power to an EX9214 Switch
Before you begin connecng DC power to an EX9214 switch:
• Ensure that you have taken the necessary precauons to prevent Electrostac discharge (ESD)
damage (see
Prevenon of Electrostac Discharge Damage
).
• Ensure that you have connected the switch chassis to earth ground.
CAUTION: To meet safety and electromagnec interference (EMI) requirements and to
ensure proper operaon, you must connect EX9214 switches to earth ground before
you connect them to power. For installaons that require a separate grounding
conductor to the chassis, use the protecve earthing terminal on the switch chassis to
connect to earth ground. For instrucons on connecng an EX9214 switch to ground
using a separate grounding conductor, see
Connect Earth Ground to an EX Series
Switch
.
• Install the power supply in the chassis. See "Installing a DC Power Supply in an EX9214 Switch" on
page 221.
Ensure that you have the following parts and tools available to connect DC power to an EX9214 switch:
• ESD grounding strap
• DC power source cables (not provided) with the cable lugs (provided) aached.
179