Table 7: Environmental Specifications for the SRX300 Services Gateway
ValueDescription
No performance degradation up to 10,000 ft
(3048 m)
Altitude
5% to 95%, noncondensingRelative humidity
•
Operational temperature—32° F (0° C) to
104° F (40° C)
•
Nonoperational temperature—4° F (-20°
C) to 158° F (70° C)
Temperature
15.4 WAverage power consumption
12 VDC, 2.8 A maximumDC Input rating
85 BTU/hrAverage heat dissipation
0 dB (fanless)Noise level
Related
Documentation
Site Preparation Checklist for the SRX300 Services Gateway on page 14•
• General Site Installation Guidelines for the SRX300 Services Gateway on page 16
• SRX300 Services Gateway Physical Specifications on page 13
Site Preparation Checklist for the SRX300 Services Gateway
Table 8 on page 14 provides a checklist of tasks you need to perform when preparing a
site for installing the SRX300 Services Gateway.
Table 8: Site Preparation Checklist for SRX300 Services Gateway
Installation
NotesDatePerformed By
Additional
InformationItem or Task
Environment
“SRX300
Services
Gateway
Environmental
Specifications”
on page 13
Verify that
environmental factors
such as temperature
and humidity do not
exceed device
tolerances.
Power
Copyright © 2016, Juniper Networks, Inc.14
SRX300 Services Gateway Hardware Guide