Programming and Auditing Locks
5–8 PKG 3114 0106
E-Plex Advanced ACS User’s Guide
16. Tap OK. The upload is successful. The M-Unit returns to the E-Plex ACS main screen.
17. Tap Disconnect to properly disconnect the M-Unit from the lock.
18. Repeat steps 3–17 to program additional doors.
Auditing Locks
Before you can audit locks, you must select the number of records you want to see each time
you do an audit. The default is 500 and the maximum is 30,000. To select the number of
records, tap E-Plex ACS and select Preferences from the drop-down menu. Under Audit
Records, select the number—any number between 50 and 30,000. The preference is saved
even after you log out. To change the number of records, return to the Preferences menu.
You can also select audits from the last 7 days, the last 30 days, or new audits only.
Transferring Files from the Lock to the M-Unit
1. Go to the door you want to audit.
2. On the pushbuttons, enter one of the following sequences as applicable:
# Master PIN # 900#
# Manager PIN # 900#
# M-Unit PIN #
Note: Hereinafter, these codes will be referred to as credentials.
3. The lock now enters the Communication Mode, indicated by alternate green and red
LEDs flashing every second for up to 30 seconds.