11.6.25.13Error24-17(emergencycode7307h)
Cause: Channel 3 Initialization, SSI: parity error, position data from encoder
Suggested steps:
Initializationencoder
channel3
l Errorduringtheinitializationroutinesof
encoderchannel3.
l Inanycaselookatinitoutputsinthemessage
windowoftheDriveManager.
l Themostcommoncauseoferroristhewiring
totheencoder.
11.6.25.14Error24-20(emergencycode7307h)
Cause: Channel 3 Initialization, SSI: encoder monitoring
Suggested steps:
Check whether the encoder is correctly connected
Initializationencoder
channel3
l Errorduringtheinitializationroutinesof
encoderchannel3.
l Inanycaselookatinitoutputsinthemessage
windowoftheDriveManager.
l Themostcommoncauseoferroristhewiring
totheencoder.
ID No.: 0842.26B.5-01Date: 09.2020
ServoOne- Device Help
407
11 Alarms & warnings
11.6.25.15Error24-38(emergencycode7307h)
Cause: Channel 3 Initialization, EndDat 2.1: error, 'PositionBits' read from encoder
Suggested steps:
Number of clocks to transmit the position from the encoder. No further information
available. Please contact your service provider.
Initializationencoder
channel
l Thisisprobablyaninternalproblemofthe
encoder!
l Inanycaselookatinitoutputsinthemessage
windowoftheDriveManager.
11.6.25.16Error24-40(emergencycode7307h)
Cause: Channel 3 Initialization, Np: error from review of parameters 'Lines' and
'NominalIncrement'
Suggested steps:
Please check this parameters.
Initializationencoder
channel
l Thisisprobablyaproblemofthe
parameterization!
l Inanycaselookatinitoutputsinthemessage
windowoftheDriveManager.