11.6.25.9Error24-9(emergencycode7307h)
Cause: Channel 3 Initialization, EndDat 2.1: CRC error, parameter data from
encoder
Suggested steps:
The transmission is probably disturbed. Please check the wiring to the encoder.
Initializationencoder
channel3
l Errorduringtheinitializationroutinesof
encoderchannel3.
l Inanycaselookatinitoutputsinthemessage
windowoftheDriveManager.
l Themostcommoncauseoferroristhewiring
totheencoder.
11.6.25.10Error24-10(emergencycode7307h)
Cause: Channel 3 Initialization, EndDat 2.1: not allowed write operation to write
protected cells or protection cells of the encoder
Suggested steps:
No further information available. Please contact your service provider.
Initializationencoder
channel
l Thisisprobablyasoftwareproblem!
l Inanycaselookatinitoutputsinthemessage
windowoftheDriveManager.
ID No.: 0842.26B.5-01Date: 09.2020
ServoOne- Device Help
406
11 Alarms & warnings
11.6.25.11Error24-15(emergencycode7307h)
Cause: Channel 3 Initialization, SSI: 'MultiTurn' from parameter (573) ENC_CH1_
MultiT
Suggested steps:
Change the input of the multiturn bits of the parameter.
Initializationencoder
channel
l Thisisprobablyaproblemofthe
parameterization!
l Inanycaselookatinitoutputsinthemessage
windowoftheDriveManager.
11.6.25.12Error24-16(emergencycode7307h)
Cause: Channel 3 Initialization, SSI: 'SingleTurn' from parameter (574) ENC_CH1_
SingleT
Suggested steps:
Change the input of the singleturn bits of the parameter.
Initializationencoder
channel
l Thisisprobablyaproblemofthe
parameterization!
l Inanycaselookatinitoutputsinthemessage
windowoftheDriveManager.