EasyManua.ls Logo

Keba ServoOne junior - Page 429

Keba ServoOne junior
493 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
11.6.37.4Error39-3(emergencycode2350h)
Cause: Maximum phase difference detected
Suggested steps:
Thecontrolsystemfailedto
trackthereferencevalue
l Pleasecheckiftheaxisisblocked.
l Trytoreduceaccelerationordeceleration.
l Ifreferencespeedishigherthanthemotor
ratedspeed,pleasecheckfieldweakening
settings.Infield-weakeningrange,the
availabletorquepercurrentisreduced.
Thisissueisprobably
causedbyanunsuitable
parametersetting.
l Saveyourparametersetforalaterrestore.
l See'historyofparameterchanges'andundo
thelatestchanges.
l Pleasecheckyourparametersetfor
implausiblesettings.
l Pleasesetdevicetofactorysetting,restart,and
seeiftheerroroccursagain.
l Whenreportingthiserrortoyourservice
partner,pleaseincludeyourdevice's
parametersetting.
ID No.: 0842.26B.5-01Date: 09.2020
ServoOne- Device Help
429
11 Alarms & warnings
11.6.37.5Error39-4(emergencycode2350h)
Cause: TWIN-Monitoring: position difference between master and slave is too large
Suggested steps:
Thecontrolsystemfailedto
trackthereferencevalue
l Pleasecheckiftheaxisisblocked.
l Trytoreduceaccelerationordeceleration.
l Ifreferencespeedishigherthanthemotor
ratedspeed,pleasecheckfieldweakening
settings.Infield-weakeningrange,the
availabletorquepercurrentisreduced.
Thisissueisprobably
causedbyanunsuitable
parametersetting.
l Saveyourparametersetforalaterrestore.
l See'historyofparameterchanges'andundo
thelatestchanges.
l Pleasecheckyourparametersetfor
implausiblesettings.
l Pleasesetdevicetofactorysetting,restart,and
seeiftheerroroccursagain.
l Whenreportingthiserrortoyourservice
partner,pleaseincludeyourdevice's
parametersetting.
11.6.37.6Error39-5(emergencycode2350h)
Cause: TWIN-Monitoring: Power fail on remote device
Suggested steps:
-

Table of Contents