Load Edge Series
48 Operations for Load Mode
How to change response speed
(1) In Constant Current and External Control modes
Make sure if it is in CC mode or Ext. Control mode.
In the LOAD CONTROL menu, press F2 key to display a window where you can
change the value.
Use ten keys to input value.
Press ENT key to confirm the value and the value becomes effective
Fig. 5-3-1 Load response setting for CC and Ext. Ctrl modes
(2) In Constant Voltage mode
Make sure if it is CV mode.
In the LOAD CONTROL menu, press F2 key.
Turn the rotary knob to select fast or slow. .
Press ENT key to confirm the value and the value becomes effective
Fig. 5-3-2 Load response setting for CV mode
5.4 Current limit setting
You can limit the load current. The current limit is effective regardless of the load mode
selected.
This function allows you to prevent to flow too large a current in CV mode etc. to protect
devices.
How to change current limit
In the LOAD CONTROL menu, press F1 key to display a window where you can
change the value.
Use ten keys to input value.
Press ENT key to confirm the value and the value becomes effective
P
u
s
h
F
1
K
e
y
P
u
s
h
F
2
K
e
y
Fig. 5-4-1 Current limit setting
For more detailed about current limit refer to 7.1 Over current limit .
F
a
s
t
S
l
o
w

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the KEISOKU GIKEN LOAD EDGE Series and is the answer not in the manual?

KEISOKU GIKEN LOAD EDGE Series Specifications

General IconGeneral
BrandKEISOKU GIKEN
ModelLOAD EDGE Series
CategoryMeasuring Instruments
LanguageEnglish