78 Alarms
7.4 Reverse connection alarm
This will be activated when reverse current is detected.
Model
Threshold current
ELZ-175
-1.5A(typ)
Table 7-4-1 Threshold current for Reverse connection protector
FIG. 7-4-1 Display of reverse connection alarm
This is alarm only; the load section wont be protected.
When an alarm is issued, if you find a phenomenon of a trouble like abnormal
smell, sound, please stop using immediately, and ask us for repair.
To detect this alarm, reverse connection voltage needs -0.6V (Typ) or more.
If alarm is occurred during BIAS Unit on, device turns BIAS Unit off
automatically.