Page #196 background image
Networking
February 2012 5-2 P/N 06-237058-001
Figure 5-1. Typical Networked ARIES NETLink System
CPD 7052
A
G
E
N
T
R
E
L
E
A
S
E
Pre-Alarm/Pre-Release
Notification Appliance
Agent-Release
Notification Appliance
Specia
l Extinguishin
g System
Pre-Action
-Sprinkler System
Manual Release Station
CPD 7052
PSD 7152
7654321
PC PC PC PC
(+) (-) (+) (-)
8
A
SW
B
SW
(+)
LED
(-)
LED
FIRE
ALARM
LIFT
AI
RDCM
A
G
E
N
T
R
E
L
E
A
S
E
Pre-Alarm/Pre-Release
Notification Appliance
Agent-Release
Notification Appliance
Specia
l Extinguishin
g System
Manual Release Stations
CPD 7052
PSD 7152
THD 7252
7654321
PC PC PC PC
(+) (-) (+) (-)
8
A
SW
B
SW
(+)
LED
(-)
LED
FIRE
ALARM
LIFT
AI
765
4321
PC PC P C PC
(+) (-) (+) (-)
N/C
COM N/O
AO
RDCM
Notification Appliances
Manual
Alarm Station
(Typical)
CPD 7052
PSD 7152
7654321
PC PC PC PC
(+) (-) (+) (-)
8
A
SW
B
SW
(+)
LED
(-)
LED
FIRE
ALARM
LIFT
AI
765
4321
PC P C PC PC
(+) (-) (+) (-)
N/C
COMN/ O
AO
A
G
E
N
T
R
E
L
E
A
S
E
Pre-Alarm/Pre-Release
Notification Appliance
Agent-Release
Notification Appliance
Specia
l Extinguishin
g System
Manual Release Station
Specia
l Extinguishin
g System
A
G
E
N
T
R
E
L
E
A
S
E
Pre-Alarm/Pre-Release
Notification Appliance
Agent-Release
Notification Appliance
CPD 7052
765
4321
PC PC PC PC
(+) (-) (+ ) (-)
N/C
COMN/ O
AO
INTERFACE MODULE
FM
APPROVED
IN
OUT
RXTX
RXTX
GND
AIM
AnaLAS
ER II
7654321
PC PC PC PC
(+) (-) (+) (-)
8
A
SW
B
SW
(+)
LED
(-)
LED
FIRE
ALARM
LIFT
AI
CPD 7052
PSD 7152
7654321
PC PC PC PC
(+)(-)(+)(-)
8
A
SW
B
SW
(+)
LED
(-)
LED
FIRE
ALARM
LIFT
AI
765
4321
PC PC P C PC
(+) (-) (+) (-)
N/C
COM N/O
AO for Contro
l Functions
(Typical)
PSD 7152
7654321
PC PC PC PC
(+) (-) (+) (-)
8
A
SW
B
SW
(+)
LED
(-)
LED
AI
Notification Appliances
7654321
PC PC PC PC
(+) (-) (+) (-)
8
A
SW
B
SW
(+)
LED
(-)
LED
AI
Sprinkler Supervision
(Typical)
Sprinkler Supervision
(Typical)
Channe
l 1
Channe
l 2 (Optiona
l)
Node 1
Node 2
Node 3
Node N

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kidde Fire Systems ARIES NETLink and is the answer not in the manual?

Kidde Fire Systems ARIES NETLink Specifications

General IconGeneral
BrandKidde Fire Systems
ModelARIES NETLink
CategoryControl Unit
LanguageEnglish

Related product manuals