EasyConnect 1 EasyConnect 2
SHE
SHE SHE SHE SHE SHEVent
Vent Vent Vent Vent Vent
Area DIP switch
Setting for
channel 1 (on the
network board
Area DIP switch
Setting for
channel 1 (on the
network board
Area DIP switch
Setting for
channel 1 (on the
network board
Area DIP switch
Setting for
channel 2 (on the
network board)
Area DIP switch
Setting for
channel 2 (on the
network board)
Area DIP switch
Setting for
channel 2 (on the
network board)
Channel 1 Channel 1
Channel 1
Channel 2 Channel 2 Channel 2
EasyConnect 3
imaginary transmission line imaginary transmission line
Drive line 1 Drive line 1 Drive line 1Drive line 2 Drive line 2 Drive line 2
1 5
2 6
3 7
4 8
1 5
2 6
3 7
4 8
SHE-
Area 1
SHE-
Area 2
SHE-
Area 2
Vent-
Area 1
Vent-
Area 1
Vent-
Area 1
Vent-
Area 2
SHE-
Area 1
SHE-
Area 1
Example 2: Networking with 3 EasyConnect control panels, 2 SHE areas and 2 ventilation areas as well as
SHE and ventilation areas together.
EasyConnect 1:
SHE manuel call point or automatic detector (also FAS input) of channel 1 activates drive line 1 (SHE area 1).
Via the imaginary transmission line 1 (area DIP switch 1 SHE) also drive line 1, channel 1 (SHE area 1) to
EasyConnect 2 and drive line 1, channel 1 (SHE area 1) to EasyConnect 3.
SHE manuel call point or automatic detector (also FAS input) of channel 2 activate drive line 2 (SHE area 1).
Via the imaginary transmission line 2 (area DIP switch 2 SHE) also drive line 2, channel 2 (SHE area 2) to
EasyConnect 2.
Vent switch of channel 2 activates drive line 2 (ventilation area 1).
Via the imaginary transmission line 1 (area DIP switch 5 Vent) also drive line 1, channel 1 (ventilation area 1)
to EasyConnect 2 and drive line 2, channel 2 (ventilation area 1) to EasyConnect 3.
EasyConnect 2:
SHE manuel call point or automatic detector (also FAS input) of channel 1 activates drive line 1 (SHE area 1).
Via the imaginary transmission line 1 (area DIP switch 1 SHE) also drive line 1, channel 1 (SHE area 1) to
EasyConnect 1 and drive line 1, channel 1 (SHE area 1) to EasyConnect 3.
SHE manuel call point or automatic detector (also FAS input) of channel 2 activate drive line 2 (SHE area 2).
Via the imaginary transmission line 2 (area DIP switch 2 SHE) also drive line 2, channel 2 (SHE area 2) to
EasyConnect 1.
Vent switch of channel 1 activates drive line 1 (ventilation area 1).
Via the imaginary transmission line 1 (area DIP switch 5 Vent) also drive line 2, channel 2 (ventilation area 1)
to EasyConnect 1 and drive line 2, channel 2 (ventilation area 1) to EasyConnect 3.
EasyConnect 3:
SHE manuel call point or automatic detector (also FAS input) of channel 1 activates drive line 1 (SHE area 1).
Via the imaginary transmission line 1 (area DIP switch 1 SHE) also drive line 1, channel 1 (SHE area 1) to
EasyConnect 1 and drive line 1, channel 1 (SHE area 1) to EasyConnect 2.
Vent switch of channel 1 activates drive line 1 (ventilation area 2).
Vent switch of channel 2 activates drive line 2 (ventilation area 1).
Via the imaginary transmission line 1 (area DIP switch 5 Vent) also drive line 2, channel 2 (ventilation area 1)
to EasyConnect 1 and drive line 1, channel 1 (ventilation area 1) to EasyConnect 2.
SHE Vent
SHE Vent
EasyConnect+