EasyManua.ls Logo

Kioti DK6010 - Engine Check Warning Lamp

Kioti DK6010
242 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4
-
26 DK6010
CEL
ON
TD2O424E
3. Stage 3 warning lamp for DPF
clogging
: DPF Soot Loading Level 200%
or higher
Passive regeneration prohibited
Engine RPM limit (below 1.500
rpm)
If the DPF is still not regenerated
even in this state, the Check engine
lamp comes on and the DPF needs
to be replaced.
WARNING
In the warning level 3 (CEL lamp
ON), both manual and auto-
matic regeneration processes
cannot be performed.
When the DPF warning lamp comes
on, make s ure to perform the
manual regeneration as the active
regeneration cannot be performed.
Enabling condition for manual
regeneration
- Clutch engaged
- Brake ON
- Engine rpm Idle state
If any of the above conditions is
not met during regeneration, the
regeneration mode is deactivated.
Other general operation can-
not be performed during the
manual regeneration process.
During regeneration, the en-
gine speed is maintained
- at 1.500 rpm for 10 minutes
- at 2.600 rpm for 25 minutes
- at 1.600 rpm for 3 minutes
This lamp on when any major electric
device or engine fuel system is mal-
functioning.
If you can see the flashing lamp,
please contact to your KIOTI dealer.
ENGINE CHECK WARNING LAMP
CEL
TD2O425E
TD210-EEC인증용-DK6010H,DK6010C,DK626 26 2018-11-28 오후 1:51:36