1.4.2 The digital servo amplifiers of the series SERVOSTAR 600
Servoamplifiers of the SERVOSTAR 640/670 series are described in additional manuals.
Standard version
l
6 current ratings (1.5 A -Europe only-,3A,6A,10A,14A,20A)
l
three instrument widths : 70 mm for 1.5A up to 10A rated current
100 mm for 14A rated current
120 mm for 20A rated current
l
wide range of rated voltage (3x208V
–10%
to 3x480V
+10%
)
l
shield connection directly at the servo amplifier
l
two analog setpoint inputs
l
integrated CANopen (default 500 kBaud), for integration into CAN bus systems and for
setting parameters for several amplifiers via the PC-interface of one amplifier
l
integrated RS232, electrically isolated, integrated pulse-direction interface
Open architecture
l
open hardware and software architecture
l
slot for an expansion card
l
integrated macro language, including compiler
l
prepared for all conceivable customer-specific extensions
Options
l -AS- built-in safety relay (personnel-safety starting lock-out), ð p. 63
l I/O expansion card, ð p. 68
l PROFIBUS DP expansion card, ð p. 72
l SERCOS expansion card, ð p. 74
l DeviceNet expansion card, ð p. 76
l Ethernet expansion card, ð p. 78
l Single Axis Controller expansion card, ð p. 80
l
-2CAN- Expansion module, separated connectors for CAN bus and RS232, ð p. 84
l
Third party expansion cards (ModBus, FireWire, LightBus etc. - contact distributors for further
information)
1.4.3 Operation directly from supply
Electrical supply
l
Directly off grounded 3 phase system,
230V
-10%
... 480V
+10%
,50Hz,
208V
-10%
... 480V
+10%
,60Hz
TN-system or TT-system with grounded neutral point, max. 5000 rms symmetrical amperes.
Connection to other mains supply networks only with insulating transformer ð p. 16
l
Fusing (e.g. fusible cutout) provided by the user
l
single-phase supply (e.g. for setup) is possible
Auxiliary supply voltage 24VDC
l
Electrically isolated, internal fusing (3.15 AT), from an external 24VDC psu, e.g. with insulating
transformer
Power input filter
l
Interference suppression filter for the supply input (to Class A) is integrated
l
Interference suppression filter for the 24V aux. supply (to Class A) is integrated
14 SERVOSTAR
®
601...620 Installation Manual
General 03/04 Kollmorgen

Table of Contents

Other manuals for Kollmorgen SERVOSTAR 601

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kollmorgen SERVOSTAR 601 and is the answer not in the manual?

Kollmorgen SERVOSTAR 601 Specifications

General IconGeneral
BrandKollmorgen
ModelSERVOSTAR 601
CategoryAmplifier
LanguageEnglish

Related product manuals