EasyManuals Logo

Kollmorgen SERVOSTAR 601 Assembly And Installation Guide

Kollmorgen SERVOSTAR 601
98 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #94 background imageLoading...
Page #94 background image
6.3 Glossary
C Clock Clock signal
Common-mode voltage The maximum amplitude of a disturbance (on both
inputs) which a differential input can eliminate
CONNECT- modules Modules built into the servo amplifier, with integrated
position control, which provide special versions of the
interface for the connection to the higher-level control
Continuous power of regen circuit Mean power which can be dissipated in the regen circuit
Counts Internal count pulses, 1 pulse = 1/2
20
turn
-1
Current controller Regulates the difference between the current setpoint
and the actual value to 0
Output: power output voltage
D DC-link Rectified and smoothed power voltage
Disable Removal of the enable signal (0V or open)
E Enable Enable signal for the servo amplifier (+24V)
F Final speed Maximum value for speed normalization at ±10V
Fieldbus interface CANopen, PROFIBUS, SERCOS etc.
G GRAY-code Special method of representing binary numbers
H Holding brake Brake in the motor, which can only be used when the
motor is at a standstill
I I²t threshold Monitoring of the actually required r.m.s. current
Input drift Temperature and age-dependent alteration of an analog
input
Incremental encoder interface Position signaling by 2 signals with 90° phase
difference, not an absolute position output
Ipeak, peak current The effective value of the peak current
Irms, effective current The r.m.s. value of the continuous current
K Kp, P-gain Proportional gain of a control loop
L Limit-switch Switch limiting the traverse path of the machine;
implemented as n.c. (break) contact
M Machine The complete assembly of all connected parts or
devices, of which at least one is movable
Monitor output Output of an analog measurement
Motion-block Data packet with all the position control parameters
which are required for a motion task
Multi-axis system Machine with several independently driven axes
N Natural convection Free movement of air for cooling
O Optocoupler Optical connection between two electrically
independent systems
94 SERVOSTAR
®
601...620 Installation Manual
Appendix 03/04 Kollmorgen

Table of Contents

Other manuals for Kollmorgen SERVOSTAR 601