3.2.4.4 Set delay time to hold the film knife (screen 2.4)
The Grand Total screen shows the delay in seconds to hold the film knife
closed, after the number of pulses has been counted (page 3‑9). The value
range is 0.0...9.9 and the default is 0.5 seconds.
3.2.4.5 Set duration time of the film release (screen 2.5)
The Baled/hr screen shows the duration of the film release after the delay
time before the film release (page 3‑10) has elapsed. The duration value can
be stored to 10 seconds and the default value is 2.0 seconds.
3.2.4.6 Set the delay time to reduce the speed (screen 2.6)
The RPM/min. screen shows the delay in seconds after the target wrap
rotation value minus one is reached (page 3‑6). The value range is 0.0...9.9
and the default is 0.5 seconds.
0.0
◄ ▼
0.0
◄ ▼
0.0
◄ ▼
3-10 Operation
W-H003.1403EN