3.7 Move the Attis to the maintenance position
Make sure there are no persons in the area when you move the Attis to
the maintenance position.
Procedure
1. Stop driving the tractor.
2. Lift the wrapping table to the top position.
3. Switch off the E‑link manual controller.
4. Switch off the tractor.
5. Close the valve to keep the wrapping table in the top position.
1. Valve - A. Open - B. Closed
Figure 18. Maintenance position wrapping table and discharge table
WARNING
Operation 3-19