Figure 44. DIMM installation
Step 1. Make sure the retaining clips are in the fully-open position; then, align the keys on the DIMM with
the connector.
Step 2. Firmly press both ends of the DIMM straight down into the connector until the retaining clips snap
into the locked position.
Step 3. If you are installing additional DIMMs, do so now.
After you install the DIMM, complete the following steps:
1. Reinstall the air baffle if it is removed (see
“Install the air baffle” on page 51).
2. Install the node if needed (see
“Install a node” on page 101).
3. Reconnect power cords and all external cables.
Dust filter replacement
Use this procedure to remove or install the dust filter.
Remove the dust filter in locking bezel
Use this information to remove the dust filter in locking bezel.
Before you remove the dust filter in locking bezel, complete the following steps:
1. Read the following sections to ensure that you work safely.
•
“Safety” on page iii
• “Installation Guidelines” on page 37
2. Turn off the server. Disconnect the power cords and all external cables (see “Power off the server” on
page 16
).
3. Remove the node from the enclosure if needed (see
“Remove a node” on page 98).
4. It is required to have dust filter when server is in operation.
To remove the dust filter in locking bezel, complete the following steps:
Step 1. Open the latch to remove the dust filter holder out of the locking bezel.