25. Press ENTER. The unit will display MAX DEPTH.
26. Press ENTER. The unit will display the factory default Max Depth (i.e. if feet/ inches were
selected as the Depth Unit the LevelCom will display 31’ 0.0”, 62’ 0.0” or 90’ 0.0”
depending on the installed sensor).
27. Press UP or DOWN to scroll to the maximum vertical dimension of the tank in the Depth
Unit of measure you chose in step #5 above.
28. Press ENTER to save the dimension. SAVING will appear briefly on the display and the
display will shift to MAX VOLUME or MAX WEIGHT indicating the dimension has been
recorded.
Note: The configuration of the Tank Table is determined by the selection of Weight, Volume,
and Display Units. If neither Volume nor Weight was selected then the unit will not display
TANK TABLE and will instead display BUBBLER TO BOTTOM. If this is the case please
proceed to step 32.
29. At MAX VOLUME/WEIGHT press ENTER. The unit will display 0.
30. Press UP or DOWN to scroll to the maximum volume/weight of the tank in the units of
measure selected above.
31. Press ENTER to save the parameter. SAVING will appear briefly on the display and the
display will shift to D9 indicating the selection has been recorded.
Note: D9 will not appear if a Maximum Volume/Weight is not entered. In this case the unit
will display BUBBLER TO BOTTOM.
Note: A Tank Table is required to configure the LevelCom 100 to an irregular shaped tank. If
this feature is required please refer to page 48, Advanced Programming for instructions.
32. At BUBBLER TO BOTTOM press ENTER. The unit will display 0.0.
33. Press UP or DOWN to scroll to the bubbler to bottom distance using the Depth Units you
selected in step #5 above.
34. Press ENTER to save. SAVING will appear briefly on the display and the display will shift
to MAX DEPTH.
Note: If you have installed the Automatic Specific Gravity option then the display will shift to
S G DISTANCE.
35. At S G DISTANCE press ENTER. Unit will display 0.0.