User attendance messages (0–99.99)
User attendance messages (099.99)
Error code Description Action
31.21 Capactive Toner Level Sensing (CTLS) reading out of
range.
Go to
“CTLS service check” on page 100.
31.22 Excessive CTLS noise. Go to
“CTLS service check” on page 100.
31.23 Abrupt change detected in CTLS reading. Go to
“CTLS service check” on page 100.
31.25 CTLS calibration capacitor reading is too low Go to
“CTLS service check” on page 100.
31.40 Toner cartridge smart chip error Go to
“Toner cartridge smart chip contact service
check” on page 87.
31.41 Toner cartridge I2C packet timeout Go to
“Toner cartridge smart chip contact service
check” on page 87.
31.42 Toner cartridge I2C packet has been sent but code
timed-out on receiving the data (callback)
Go to
“Toner cartridge smart chip contact service
check” on page 87.
31.43 Toner cartridge security error in the send challenge
sequence
Go to
“Toner cartridge smart chip contact service
check” on page 87.
31.44 Toner cartridge ROM signature error Go to
“Toner cartridge smart chip contact service
check” on page 87.
31.45 Toner cartridge stuck busy (Status register and/or CRI
Arbiter register report busy)
Go to
“Toner cartridge smart chip contact service
check” on page 87.
31.46 Toner failed to replenish into the imaging unit Go to
“Cartridge gearbox service check” on
page 102.
31.60 Imaging unit smart chip error Go to
“Imaging unit smart chip contact service check”
on page 88.
31.61 Imaging unit I2C packet timeout Go to
“Imaging unit smart chip contact service check”
on page 88.
31.62 Imaging unit I2C packet has been sent but code timed-
out on receiving the data (callback)
Go to
“Imaging unit smart chip contact service check”
on page 88.
31.63 Imaging unit security error in the send challenge
sequence
Go to
“Imaging unit smart chip contact service check”
on page 88.
31.64 Imaging unit ROM signature error Go to
“Imaging unit smart chip contact service check”
on page 88.
31.65 Imaging unit stuck busy (status register and/or CRI
Arbiter register report busy)
Go to
“Imaging unit smart chip contact service check”
on page 88.
31.66 Toner failed to replenish into the imaging unit Go to
“Cartridge gearbox service check” on
page 102.
32.01 Capacity Class/ Model compatibility mismatch. The
supplies CC/MC is not compatible with the printer's
CC/MC setting.
Go to
“Toner smart chip compatibility service check
on page 88.