Maintenance 5
Engine
¾ Unscrew the sight glass (1) and wipe out
with a clean cloth.
If necessary, completely dismantle the water
trap and blow out with compressed air.
Cleaning the pressure control device
at the changing particle filter (special
equipment)
NOTE
Only for particle filters with a changing particle
filter system.
¾ Removethehoseclip(1).
¾ Remove the hose (2) from the water trap
(3).
¾ Blow dry compressed air through the hose
and cooling coil towards the filter entrance
chamber.
¾ Reattach the hose and secure with the hose
clip.
Operating Instructions – 394 807 10 01 EN – 07/2011 153