LOADRITE PRO OPERATING MANUAL
71
16 Error Messages
Bouncing Load
If the lift arms are bouncing significantly while weighing, an error occurs.
This can happen if, for example, the loader is driven over uneven ground
while lifting the load.
The Loadrite can detect a bouncing load and if this occurs, the indicator
displays the message Bouncing Load.
Depending on the installation of the Loadrite, there are two possibilities
1. No weight is displayed and hence there is no weight to add. You
should repeat the lift. Avoid uneven ground as you lift through or near
the trigger point.
2. Weighing Error is turned off and a weight is displayed. You can add
the weight to the total (bearing in mind that the weight measurement is
not reliable) or you can ignore this weight and repeat the lift smoothly.
Check Power
The Loadrite has detected that the power supply has reached the unstable
level. Check that the power source is stable and between +12V and +32 V.
Check Transducer
The Loadrite has detected an error in the pressure transducer signal input.
This indicates a fault in either the pressure transducer or the cable that
connects the transducer.
Check Trigger
The Loadrite has detected a fault in the trigger or the cable that connects
the trigger.
Check that the lens on the optical trigger is clear and dust-free.
Check Zero
The Loadrite automatically reminds the operator to check zero occasionally.
See Check Zero Prompt on page 16.
When this message appears you need to perform zero lift.