LOADRITE PRO OPERATING MANUAL
74
Speed Changed
For accurate measurement, the speed of raising the lift arms must be
smooth, without acceleration or deceleration.
The Loadrite can detect changing speed as the arms go past the trigger
point. If this occurs, the indicator displays the message Speed Changed.
Depending on the installation of the Loadrite, there are two possibilities:
1. No weight is displayed and hence there is no weight to add. You
should repeat the lift. Avoid accelerating and decelerating at or near
the trigger sequence.
2. Weighing Error is turned off and a weight is displayed. You can add
the weight to the total (bearing in mind that the weight measurement is
not reliable) or you can ignore this weight and repeat the lift smoothly.
Too Heavy, Zero Aborted
The Loadrite zero function can only zero up to 4% of full scale.
See page 15 for details.
Warm Up Lift
This message appears if the Loadrite has been switched off for more than 1
hour.
You need to lift the bucket/forks a few times to warm up.
See the Warm Up Screen on page 5 for details.