LOADRITE PRO OPERATING MANUAL
77
18 Output / Input Connections
Transducer
1. +12V
2. Return pressure input
3. Transducer current input
4. +10 volt excitation
5. Lift pressure input
6. Shield
7. Ground
Power/Control
1. Negative supply (ground)
2. Positive supply
3. Remote button 2 (clear)
4. Remote button 1 (add)
5. N.C.
6. Trigger 1: Magnetic or Optical trigger / Interlock
7. N.C.
8. Positive supply to Trigger 2
9. N.C.
10. Trigger 2: Rotary trigger / Interlock
11. N.C.
12. N.C.
13. Ground output
14. Positive output
15. Ground output
Printer/Logger
1. Negative supply to printer
2. Positive supply to printer
3. +12V output
4. N.C.
5. Reserved
6. Printer RS232 output
7. Printer busy input
8. EDP RS232 input
9. EDP RS232 output
10. Ground output
11. Reserved
12. N.C.

Table of Contents