LOADRITE PRO OPERATING MANUAL
72
Lift Under Range
The Loadrite has detected that the Lift pressure was too low.
This indicates a fault in either the pressure transducer or the cable that
connects the transducer.
Module Data Lost
The Loadrite has an ability to store data internally in the event that the Data
Logger Module LD941 is absent or full. The Loadrite will generate this
message when the internal data storage is full and some data has been lost
as a result.
You need to install a new data module immediately to avoid further loss of
data.
Module Error
The Loadrite has detected an error when writing to the LD941 data logger
module.
Check that the module is securely connected to the Loadrite.
Module Full
The Loadrite has detected that the LD941 data logger module is full.
The full module should be removed and taken to the MMS for data transfer.
No Lock
No Lock means that the interlock was not closed when lifting the load. The
interlock must be closed (or the bucket must be fully rolled back) while lifting
the load.
No weight is displayed and hence there is no weight to add.
Over Target
Over Target means that adding the lifted weight will exceed the target
value. The lifted weight can still be added by pressing the ADD key.