17 Specifications
Suitable Applications
The Loadrite measures weight by sensing the hydraulic pressure required
to lift a load. A trigger mechanism senses the position of the lifting arms.
Typical vehicles using the Loadrite system are:
Front end loaders (bucket and/or fork)
Forklift trucks
Weighing Accuracy
Typical accuracy is ±1% for most bucket loaders. This may vary with
different machine types and installation options.
Minimal Weighing Delay
Weighing delay is minimal, because the weighing function is carried out
during a normal lift. Loader should be stationary.
Power requirements
Supply Voltage 12 to 32 Volts DC
Supply current Loadrite indicator: 160mA
typical, 350mA max.
Loadrite printer: 50mA standby,
4A peak.
Automatic transient suppression. Exceeds relevant SAE specifications for
DC automotive power supply transients.
Signal Inputs and Outputs
Pressure transducer input 1 - 20mA (0-100%).
Trigger input Trigger 1: Magnetic or Optical.
Pull-up resistor requiring switch
to ground.
Trigger 2: Rotary. Pulse width
modulated: 0 - 5V.
Serial communications. RS232C protocol to printer and
data logger