TYPES OF OPERATIONS
Logicube Falcon
®
-Neo User’s Manual 62
5.2.3.1.3 LBA
The LBA icon will bring up the LBA settings screen. The
user can adjust the percentage or the number of blocks
of the drive to hash and where to start the hash. By
default, the length is set to 100% (whole drive) and the
starting percentage is set to 0% (start of the drive).
When the Falcon-NEO finishes hashing the drive, the
following screen will appear showing the task completed.
Tap the (Info) icon on the left of the completed
screen to see both the expected hash value and the
computed hash value.
5.2.3.2 Case Verify
There are two settings in the Verify Hash screen:
Primary Will verify just one hash value (For example, if SHA-1 or MD5
was selected during the image process).
Both Will verify both SHA-1 and MD5 if the SHA-1+MD5 hash was
selected during the image process.