TYPES OF OPERATIONS
Logicube Falcon
®
-Neo User’s Manual 66
DOD – Choosing this will instruct the Falcon-
NEO to perform a 7-pass wipe conforming to
the DoD 5220.22-M standards.
CUSTOM – Choosing this will allow the user to
specify how many wipe passes will be performed
and what values each pass will be written on
each of the passes selected.
5.3.2.2.2 HPA/DCO/ACS3
The HPA/DCO/ACS3 button will open the
HPA/DCO/ACS3 option for wiping. If the drive to be
wiped has HPA, DCO, and/or ACS3 that need to be
wiped, select Yes for the corresponding option.
5.3.2.2.3 LBA
By default, this is set to 100% which will wipe all Logical
Block Addresses (LBAs) and will wipe the entire drive
(100%). The LBA count can be adjusted by tapping the
edit icon.
5.3.2.2.4 PASSES
This Wipe Setting will change depending on the Wipe
Pattern Mode selected.
If None was selected, this is not selectable.
If DoD was selected, all 7 passes will be pre-
filled. Users can edit the pass values by tapping
the edit icon. The default values are: 00, 01, 00,
FF, F6, 00, XX (random).
If Custom was selected, one pass will be pre-
filled with a random value. Users can edit the
pass values if desired by tapping the edit icon.
The default value for a custom pass is 00.
Editing one or more of the passes in DOD or CUSTOM
mode will bring up this screen: