Maintenance work on the carrier
7.5 Exhaust system with exhaust emission control
7 - 34 3 302 719 en Maintenance manual
GMK6300L-1
13.02.2018
Checking
Check the exhaust pipes (2) from the
engine (1) to the silencer (3) for damage.
The exhaust pipes (2) may not have any
holes or cracks.
Check that the area around the exhaust
pipes is free of loose components which
could burn by coming into contact with
the hot exhaust system.
Check the AdBlue injection nozzle (4) for
outer damage.
After checking
Start the engine.
Check the AdBlue system lamp on the instrument panel; à p. 7 - 32.
Check whether exhaust gases are leaking from any damaged places in the
exhaust system.
Switch off the engine.
If you discover any damage
Have any damaged parts of the exhaust system replaced immediately
by
Manitowoc Crane Care or an authorised GROVE dealer.
G
Risk of burns if the exhaust system is hot
During operation, the exhaust system heats up to 400 °C (750 °F). Wear
suitable gloves and wait until the exhaust system has cooled down.