Maintenance work on the carrier
7.14 Hydraulic system
13.02.2018
Maintenance manual 3 302 719 en 7 - 85
GMK6300L-1
7.14.5 Changing the ventilation filter
Reducing the
interval
• Under difficult operating conditions – at extremely sandy or dusty
locations – you must change the ventilation filters earlier than normal.
Spare parts
and t
ools
Prerequisites – The engine must be switched off and secured against unauthorised use;
à p. 2 - 3.
• Remove the cover (1).
• Change the filter (2) and fasten the cover.
M 12
Designation Quantity GROVE part no.
Filter 1 03324588
O
Risk of damage to the environment from filter residues
Store used hydraulic oil filter inserts in suitable receptacles and have them
disposed of properly by qualified personnel.