Maintenance work on the carrier
7.7 Transfer case
13.02.2018
Maintenance manual 3 302 719 en 7 - 45
GMK6300L-1
7.7 Transfer case
• Comply also with the à Running-in regulations, p. 4 - 1.
7.7.1 General inspection
• Investigate any unusual noises made by the transfer case.
• Check the transfer case and the connections for leaks. If consumables are
leaking;
à Checking the oil level, p. 7 - 45.
• Check that pipes and hoses are tightly connected and undamaged.
If any damage is found, report it to
Manitowoc Crane Care or an authorised
GROVE dealer or an authorised specialist workshop.
7.7.2 Checking the oil level
Spare parts and
tools
– Clean receptacle, approx. 5 ltr (1.3 gal);
à p. 2 - 4.
Prerequisites – The truck crane must be raised on outriggers or parked over an
inspection pit.
– The engine must be switched off and secured against unauthorised use;
à p. 2 - 3.
s
W
M 1
Designation Quantity GROVE part no.
Gasket 30 x 36 Cu DIN 7603 2 00117151

Table of Contents

Other manuals for Manitowoc Grove GMK6300L-1

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Manitowoc Grove GMK6300L-1 and is the answer not in the manual?

Manitowoc Grove GMK6300L-1 Specifications

General IconGeneral
BrandManitowoc
ModelGrove GMK6300L-1
CategoryConstruction Equipment
LanguageEnglish

Related product manuals