EasyManuals Logo
Home>Manitowoc>Construction Equipment>Grove GMK6300L-1

Manitowoc Grove GMK6300L-1 Maintenance Manual

Manitowoc Grove GMK6300L-1
370 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #152 background imageLoading...
Page #152 background image
Maintenance work on the carrier
7.12 Steering
7 - 76 3 302 719 en Maintenance manual
GMK6300L-1
13.02.2018
7.12.2 Pressure accumulator – checking the gas pressure
The gas pressure must be checked every 3000 operating hours, but in any
case no less frequently than every 12 months.
Nitrogen filled pressure accumulators (1) and
(2) are fitted for steering the axle lines.
The filling pressure at 20 °C (68 °F) is:
• Have the filling pressure checked, and if
necessary corrected, by
Manitowoc Crane
Care
or an authorised GROVE dealer or
an authorised specialist workshop.
M 12
G
Risk of accidents due to incorrect inspection.
The gas pressure test may be carried out only by an authorised official
inspector of pressure tanks or under his/her supervision or instructions.
1 89 bar (1290 psi)
2 100 bar (1450 psi)

Table of Contents

Other manuals for Manitowoc Grove GMK6300L-1

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Manitowoc Grove GMK6300L-1 and is the answer not in the manual?

Manitowoc Grove GMK6300L-1 Specifications

General IconGeneral
BrandManitowoc
ModelGrove GMK6300L-1
CategoryConstruction Equipment
LanguageEnglish

Related product manuals