Maintenance work on the carrier
7.15 Central lubrication system
13.02.2018
Maintenance manual 3 302 719 en 7 - 99
GMK6300L-1
7.15 Central lubrication system
The central lubrication system supplies the steering lever and all the
axle lines.
7.15.1 Checking the level
Grease, spare
parts, tools
– Filling pump from the tool set.
Prerequisites – The parking brake must be applied.
Checking the level
• Check the level in the grease container (1).
The grease level must be near the max.
marking.
If it is below the min. marking, the level
is too low.
If the level is too low
• Add more grease; à p. 7 - 100.
s
W
Lubricating
grease
Designation
according to
DIN 51502
Specification
Classification
GROVE part no.
Grease KP - 1K - 50 DIN 51825 03233369