Maintenance work on the carrier
7.15 Central lubrication system
13.02.2018
Maintenance manual 3 302 719 en 7 - 101
GMK6300L-1
7.15.2 Bleeding the central lubrication system
If the grease container is empty or contains bubbles, you must bleed the
central lubrication system.
The grease container (3) must be full.
Undo the connection (4).
Switch on the ignition.
Remove the cap (1) and press button (2)
once for approx. 2 seconds. Repeat the
procedure until the grease flowing from the
connection no longer contains any bubbles.
Attach the connection and the cap.
Remove any grease that emerges.
7.15.3 Triggering intermediate lubrication
Intermediate lubrication should be triggered,
after high pressure cleaning,
to check the lubrication system at all lubricating points.
Switch on the ignition.
Remove the cap (1) and press button (2)
once for approx. 2 seconds.
An intermediate lubrication cycle will be trig-
gered which lasts approxim
ately 3 minutes.
Check whether grease oozes from all the lubri-
cating points (steering lever on all axle lines).
Switch off the ignition and remove any
excess grease.