Maintenance work on the carrier
7.15 Central lubrication system
13.02.2018
Maintenance manual 3 302 719 en 7 - 101
GMK6300L-1
7.15.2 Bleeding the central lubrication system
If the grease container is empty or contains bubbles, you must bleed the
central lubrication system.
The grease container (3) must be full.
• Undo the connection (4).
• Switch on the ignition.
• Remove the cap (1) and press button (2)
once for approx. 2 seconds. Repeat the
procedure until the grease flowing from the
connection no longer contains any bubbles.
• Attach the connection and the cap.
• Remove any grease that emerges.
7.15.3 Triggering intermediate lubrication
Intermediate lubrication should be triggered,
– after high pressure cleaning,
– to check the lubrication system at all lubricating points.
• Switch on the ignition.
• Remove the cap (1) and press button (2)
once for approx. 2 seconds.
An intermediate lubrication cycle will be trig-
gered which lasts approxim
ately 3 minutes.
Check whether grease oozes from all the lubri-
cating points (steering lever on all axle lines).
• Switch off the ignition and remove any
excess grease.
• Fasten the cap.

Table of Contents

Other manuals for Manitowoc Grove GMK6300L-1

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Manitowoc Grove GMK6300L-1 and is the answer not in the manual?

Manitowoc Grove GMK6300L-1 Specifications

General IconGeneral
BrandManitowoc
ModelGrove GMK6300L-1
CategoryConstruction Equipment
LanguageEnglish

Related product manuals