Maintenance work on the superstructure
8.8 Slewing bearing
8 - 60 3 302 719 en Maintenance manual
GMK6300L-1
13.02.2018
8.8.3 General inspection
• Pay attention to any unusual running noises from the slewing bearing.
• If unusual noises occur, take a sample of the grease that has escaped.
Have
Manitowoc Crane Care examine the sample for metal residue.
• Check the slewing bearing for damage (e.g. gaskets).
If any damage is found, report it to
Manitowoc Crane Care or an authorised
GROVE dealer or your repair crew.
H
The maintenance interval specified here must be reduced if the slewing
bearing was subjected to heavy blows (falling load, load slipping).