Maintenance work on the superstructure
8.8 Slewing bearing
13.02.2018
Maintenance manual 3 302 719 en 8 - 59
GMK6300L-1
First lubrication
Remove the plate (1).
Remove the old grease from all the gear
teeth (2).
Apply a thin layer of new grease to all the
gear teeth and allow it to penetrate for about
10 minutes.
Apply a second, thicker layer of grease and
allow it to penetrate for about 30 minutes.
Attach the plate.
Subsequent lubrication
Remove the plate (1).
Apply new grease to all the gear teeth (2).
Allow it to penetrate for about 30 minutes.
Attach the plate.