Maintenance work on the carrier
7.4 Fuel system
13.02.2018
Maintenance manual 3 302 719 en 7 - 29
GMK6300L-1
7.4.3 Replacing fuel filter 2
Spare parts and
tools
Receptacle, approx. 5 ltr (1.5 gal);
à p. 2 - 4.
Torque wrench for a torque of 15 Nm (11 lbf ft).
Prerequisites The truck crane must be level and on outriggers;
à Manual de
instrucciones
.
The main boom must be fully raised;
à Manual de instrucciones.
The engine must be switched off and secured against unauthorised
use;
à p. 2 - 3.
If the fuel is dirty: Reduce the maintenance interval.
Changing
Place a receptacle under the filter (1).
Close the valve – lever (2) at right angles
to the line.
s
M 12
Designation Quantity GROVE part no.
Filter (small) 1 04161566
alternatively:
Set for both filters 1 + 2 (large + small)
1 04180966
O
Risk of environmental damage due to leaking consumables.
Always let consumables drain into suitable recep
tacles. Wipe up any
consumables that escape.
Store/dispose of consumables and any soaked equipment properly.
Ask about the applicable regulations.