Maintenance work on the carrier
7.14 Hydraulic system
13.02.2018
Maintenance manual 3 302 719 en 7 - 89
GMK6300L-1
Dispatch the oil
sample to the
laboratory
Manitowoc Crane Care gives you the opportunity to have the oil sample
analysed at our contracted laboratory. A delivery note and a protective
mailing bag are available along with the sample containers (GROVE part
no. 03141012). You will get the laboratory analysis via the Internet in a
short time.
Label the sample container prior to dispatch with
the truck crane serial number,
the date of sampling,
the number of operating hours since the last oil change and
the sampling location (e.g. gauge port on a control block).
Have the following properties of the oil sample determined by
the laboratory
the viscosity,
the viscosity index,
the contamination,
the water content.
Determining the
quality of the oil
Compare the laboratory analysis with the limit values and carry out
the specified measures if necessary.
Viscosity limit values
Viscosity ISO-VG 32 as per DIN 51524 Part 2.
Viscosity index V
i
150.
If one of these limit values has been reached/fallen short of:
Carry out an oil change; à p. 7 - 91.
Contamination limit value
Contamination according to NAS 1638 Class 7 or ISO 4406:1999
Code 18/16/13 (cleanliness class).
If this limit value has been reached/exceeded:
Replace the filters of the hydraulic system; à p. 7 - 95.
Have the hydraulic oil cleaned with a mobile filter unit until the required
cleanliness class is achieved.
Water content limit value
Water content 100 ppm.
If this limit value has been reached/exceeded:
Have the hydraulic oil cleaned with a mobile water separator until
the water content is clearly below the limit value.