Maintenance work on the carrier
7.14 Hydraulic system
13.02.2018
Maintenance manual 3 302 719 en 7 - 93
GMK6300L-1
Topping up the oil
• Remove the cover (3).
• Add new oil through a filter until the level
reaches the centre of the sight glass (1).
• Replace the gasket (2) if necessary and
fasten the cap (3).
Establishing the
operating
conditions
After having
changed the oil filters and topping up the oil, you must
re-establish the operating conditions.
Opening the valves
• Open the valves – lever (1) parallel with
the line.
s
S
Risk of damage to the hydraulic system
Cleanliness is of the utmost importance when handling hydraulic oil.
Even fresh hydraulic oil must be filtered before it is added to the tank.
S
Risk of damage to the hydraulic pumps
Open the valves prior to starting the engine.
This prevents damage to the hydraulic pumps.